Analysis of Reflux Medium Temperature Rise at Regeneration Tower and Its Optimization
Author of the article:Li Long1, He Linlin2, Wang Gang1, Ren Yusheng3, Huang Kun4
Author's Workplace:1. China Petroleum Engineering & Construction Corp. Southwest Company, Chengdu, Sichuan, 610041, China; 2. Chengdu Natural Gas Chemical Works, PetroChina Southwest Oil & Gas Field Company, Chengdu, Sichuan, 610213, China; 3. Xiangyuan Guoxin LNG Co., Ltd, Changzhi, Shanxi, 046299, China; 4. Chongqing Bojie Energy Co., Ltd
Key Words: Regeneration tower; Liquid level control; Medium temperature rise; Optimization
Abstract:
Liquid level recirculation control is
an important means of process control, which plays a key role in the production
process of rectification process, absorption and regeneration and liquid level
maintenance of the vessel.The phenomenon of medium temperature rise which occurs in
the top reflux system of MDEA regeneration tower is introduced.The reason of medium temperature
rise is systematically analyzed from the perspective of energy balance.In the system, the source of
medium temperature rise is determined, and the maximum value of temperature
rise is calculated.In
order to maintain the liquid level smoothly in the separation tank, the design
optimization measures and suggestions are proposed,which has guiding significance
for the engineering design and the operation of liquid level control in the
similar system.