Internet Workstation

Edition and Publication

Edition and Publication:
< Natural Gas and Oil > Editorial Department
Hosted by:
China Petroleum Engineering & Construction Corporation Southwest Company
Authorized by:
China Petroleum Engineering & Construction Corporation
Co-hosted by:
Overseas Research Center of Research Institute of Petroleum Exploration and Development
Editor in Chief:
Du Tonglin
Vice Editor in Chief:
Tang Xiaoyong,Pu Liming
Address:
No.6, Shenghua Road, High-tech District, Chengdu, Sichuan, China
Postal Code:
610041
Tel:
028-86014709
028-86014500
Email:
cnpc-ngo@cnpc.com.cn
Issue:ISSN 1006-5539
          CN 51-1183/TE

Links

    Your Position :Home->Past Journals Catalog->2020 Vol.6

    Discussion on the Configuration and Selection of Emergency Shut-Off Valve for Large Liquefied Hydrocarbon Spherical Tank
    Author of the article:Du Juan, Liu Yan, Han Qingfei, Li Yufeng
    Author's Workplace:China Petroleum Engineering & Construction Corp. Southwest Company, Chengdu, Sichuan, 610041, China
    Key Words:Fully pressurized liquefied hydrocarbon spherical tank; Emergency shut-off valve; Liquefied hydrocarbon; Layout scheme
    Abstract:

    In order to provide guidance on the installation and selection of emergency shut-off valve for fully pressurized liquefied hydrocarbon spherical tanks, the design for the emergency shut-off valve on the inlet and outlet pipelines of six 3000 m3 fully pressurized liquefied hydrocarbon spherical tanks for a large domestic project is studied. Comparison and analysis have been performed focusing on the basis and method for process system configuration, selection of valve body and actuator of the emergency shut-off valve. From the study, it is concluded that: 1) it is recommended to install double valves on the liquid inlet and outlet pipelines of the large liquefied hydrocarbon spherical tank, namely emergency shut-off valves and remote operation valves; 2) The emergency shut-off valve is arranged close to the spherical tank. The valve installation position shall be as close as possible to the first flange sealing surface of the spherical tank to connect the SIS safety system, interlocking with the high-high, low-low liquid level control of the spherical tank; 3) The remote operation valve is installed outside the dike and shall be easy to operate and maintain and be easily accessible. The remote operation valve shall connect with DCS process control system; 4) Pneumatic actuators are preferred for emergency shut-off valves and remote operation valves when instruction air is available. The research results can provide reference for the selection and configuration of the emergency shut-off valve for the inlet and outlet pipes of the fully pressurized liquefied hydrocarbon spherical tanks.

    CopyRight©2025Natural Gas and Oil Editorial Office Reserved 京ICP备11013578号-1