Internet Workstation

Edition and Publication

Edition and Publication:
< Natural Gas and Oil > Editorial Department
Hosted by:
China Petroleum Engineering & Construction Corporation Southwest Company
Authorized by:
China Petroleum Engineering & Construction Corporation
Co-hosted by:
Overseas Research Center of Research Institute of Petroleum Exploration and Development
Editor in Chief:
Du Tonglin
Vice Editor in Chief:
Tang Xiaoyong,Pu Liming
Address:
No.6, Shenghua Road, High-tech District, Chengdu, Sichuan, China
Postal Code:
610041
Tel:
028-86014709
028-86014500
Email:
cnpc-ngo@cnpc.com.cn
Issue:ISSN 1006-5539
          CN 51-1183/TE

Links

    Your Position :Home->Past Journals Catalog->2023 Vol.6

    Analysis of abnormal handling cases in pipeline cathodic protection during commissioning and trial operation
    Author of the article:MA Hanyue1, ZHANG Ping1, HUANG Chunrong1, TU Haibo1, MU Hua1, LI Tianlei1, GUAN Yue1, SHI Daiyan1, LI Hao1, ZOU Shaowei2, LIU Hailu1, SHANGGUAN Changhuai1
    Author's Workplace:1. CPECC Southwest Company, Chengdu, Sichuan, 610041, China; 2. PipeChina South China Branch, Maoming, Guangdong, 525000, China
    Key Words:Ethane external pipeline; Cathodic protection; Valve chamber; Current leakage; Protection potential
    Abstract:

    During cathodic protection commissioning and trial operation, the protection potential of about 20 km on both sides of the 3# valve chamber in the middle section of an ethane export transmission pipeline did not meet performance standard. In order to solve the abnormal phenomenon, the main influencing factors such as incorrect equipment debugging parameters, non-optimal setting of cathodic protection station and anode ground bed, stray current interference, poor quality of corrosion protection layer and abnormal leakage of protection current were analyzed and studied. It is preliminarily determined that the substandard protection potential is caused by abnormal leakage of current. The main causes of abnormal leakage of protection current, such as insulation joint failure or leakage, crossing casing lap, valve chamber leakage, etc., were analyzed. The abnormal leakage of valve chamber is identified. The surface area and current leakage of the ground electrode of the valve chamber in the main process area and the flare area are calculated, and the abnormal leakage is inferred to be the flare area. Checking the abnormal leakage parts of the pipeline and the grounding pole in the vent area, it is found that the self-tapping bolt of the insulation outer protection layer of the ground pipeline penetrates the corrosion protection layer and make contacts with the pipeline body, resulting in current leakage. Finally, rectification was carried out according to relevant standards and specifications, and the pipeline protection potential reached the standard requirement. The research results put forward systematic and comprehensive analysis and troubleshooting ideas and methods for the resolution of abnormal cathodic protection problems, and provide reference and suggestions for similar abnormal cathodic protection commissioning and trial operation in the future.

    CopyRight©2025Natural Gas and Oil Editorial Office Reserved 京ICP备11013578号-1